Stair Handrail Height Requirements in Ontario: The 2026 Code Guide

Stair handrail height requirements in Ontario — Darvish Inc installer measuring a handrail in Toronto

A handrail too low will not save anyone from a fall, and one too high is hard to grip. In Ontario, the height is not a matter of taste: the Ontario Building Code sets the minimum handrail height Ontario stairs must meet, and an inspector can fail a staircase that misses it by 20 mm. This guide gives you stair handrail height requirements in Ontario as installers apply them, with the exact numbers for handrails, guards and landings.

This guide walks through the two numbers that matter most for stair handrail height requirements in Ontario: the handrail at 865 mm to 1,070 mm above the tread nosing, and the guard at 900 mm inside the home and 1,070 mm outside it. You will also learn the Ontario building code stair guard height for landings, winders and decks, how to measure your own stairs, and the seven mistakes that fail inspection. By the end, you will know whether your stairs pass — and what to fix.

At Darvish Inc, our own team installs stairs and railings across Toronto and the GTA, with glass and fittings made to your exact measurements, so the advice below comes from real homes and real stairs. This guide covers stair handrail height requirements in Ontario, the code numbers behind every height, and the costliest mistakes. We serve Toronto, North York, Vaughan, Markham, Richmond Hill and Oakville.

What Is a Handrail — and What Is a Guard?

A handrail and a guard do different jobs, and the Code gives them different numbers. A handrail is what your hand grips as you climb: a rail that runs along the stair at 865 mm to 1,070 mm above the tread nosings. A guard is the barrier that stops a fall: the panel, balusters or glass standing 900 mm high on a stair and 1,070 mm high outside the home. On an open stair, the handrail sits on top of the guard; on a wall-side stair, there is a handrail but no guard.

Mixing the two up is the most common mistake in a quote. A homeowner asks for a handrail and gets a price for a guard, or the other way around. When you ask an installer for a price, name the part you mean: the handrail you grip, the guard that stops the fall, or both together. The rest of this guide keeps the two apart, so every number lands on the right part.

Stair Handrail Height Requirements in Ontario: The Numbers

Stair handrail height requirements in Ontario — measuring handrail height from the tread nosing

These are the Ontario Building Code numbers for a private staircase inside a home. Stair handrail height requirements in Ontario start with the handrail at 865 mm to 1,070 mm above the tread nosing, then the guard at 900 mm on the stair and 900 mm on a landing inside the home. Outside the home, the guard rises to 1,070 mm. The table below puts every limit in one place.

How Handrail Height Is Measured

Handrail height is measured vertically from the nosing line — a line joining the front edges of the treads — straight up to the top of the handrail. Stair handrail height requirements in Ontario are measured this way at every tread: a handrail that follows the slope keeps the same height all the way up, so measure at the bottom, the middle and the top. If the height changes along the flight, the rail was cut wrong.

Why the Maximum Rose from 965 mm to 1,070 mm

Until 2022, the handrail maximum in Ontario was 965 mm. The 2022 Code update raised it to 1,070 mm, and raised the minimum stair run from 210 mm to 255 mm. A handrail built to the code in force when the home was built is not automatically a failure because the numbers moved — but any new handrail, and any replacement, must meet the current range of 865 mm to 1,070 mm. If your handrail sits at 965 mm, it was built to the old maximum; ask your municipality before you replace it.

Requirement Code limit
Handrail height 865 mm to 1,070 mm above the tread nosing
Guard on a stair At least 900 mm high
Guard on an interior landing At least 900 mm high
Guard outside the home At least 1,070 mm high
Openings in a guard No 100 mm ball may pass
Riser height 125 mm to 200 mm
Tread run 255 mm to 355 mm
Stair width At least 860 mm clear
Guard required Above a 600 mm drop

These are the 2024 Ontario Building Code limits for a private staircase inside a home, and the Ontario Building Code handrail rules are the standard installers work to. Two numbers changed in 2022: the minimum run rose from 210 mm to 255 mm, and the handrail maximum from 965 mm to 1,070 mm. Treat the table as a planning reference, and confirm permit rules with your municipality first.

Guardrail Height for Interior Stairs in Ontario

Stair handrail height requirements in Ontario — an interior guard on a landing

Inside the home, the guard is 900 mm high — on the stair and on the landing alike. The guardrail height for interior stairs Ontario sets the same 900 mm for both, the number most people get wrong: older guides quoted 1,070 mm for an interior landing. Stair handrail height requirements in Ontario make the distinction clear: the guard rises to 1,070 mm only outside the home, on a deck or balcony. Inside, 900 mm is the number.

Landings Inside the Home

A landing inside the home takes the same 900 mm guard as the stair — not higher. The guardrail height for interior stairs Ontario is measured from the floor on a landing, straight up to the top of the guard, and the Code sets a minimum, so a taller guard still passes. But the required height is 900 mm: a quote that lists 1,070 mm for an interior landing is quoting the outside number. Check the landing separately: a landing guard lower than the stair guard is the defect an inspector finds first.

Winders, Spirals and Basement Stairs

A winder turns a corner without a landing, with triangular treads. The Code allows winders inside a home to turn no more than 90 degrees, each tread spanning 30 to 45 degrees. A true spiral staircase follows its own numbers: at least 660 mm wide, risers no more than 240 mm, treads at least 190 mm deep 300 mm from the inside handrail, and headroom of at least 1,980 mm, with the outer handrail at least 1,070 mm high. Basement stairs follow the same interior numbers, and the guardrail height for interior stairs Ontario applies to them too.

Location Handrail Guard What changes
Interior stair 865 mm to 1,070 mm At least 900 mm Same interior numbers
Interior landing No handrail needed At least 900 mm Measured from the floor
Deck or balcony 865 mm to 1,070 mm At least 1,070 mm Guard rises outdoors
Exterior steps 865 mm to 1,070 mm At least 1,070 mm Where the drop is over 600 mm
Basement stair 865 mm to 1,070 mm At least 900 mm Same as the interior stair

Stair Railing Code for Decks in Ontario

Outside the home, the guard must stand 1,070 mm high. The stair railing code for decks in Ontario sets that number for every deck, balcony and porch where the drop exceeds 600 mm, the biggest difference from the interior rules. Stair handrail height requirements in Ontario keep the handrail at 865 mm to 1,070 mm above the nosing, the same as inside — only the guard changes. A deck guard quoted at 900 mm uses the interior number, and it will fail an inspection.

Stair handrail height requirements in Ontario — a deck guard at 1,070 mm

Decks, Balconies and Porches

A deck guard is measured from the deck surface straight up to the top of the guard, and it must reach 1,070 mm at every point. The stair railing code for decks in Ontario also covers the gaps: no opening may let a 100 mm ball pass through, which sets the baluster spacing. Horizontal rails are a trap on a deck guard: the Code treats horizontal members as ladder rungs a child can climb, so a guard with horizontal rails can fail even at the right height. Use vertical balusters or glass panels instead.

Glass Railings Outdoors

Glass is the clearest choice for a deck, and it must be safety glass: tempered or laminated, meeting the CAN/CGSB-12.1 standard, so a broken panel crumbles instead of shattering. On a condo balcony, the glass must also meet the SB-13 standard for the building. The glass railing cost in Toronto guide breaks down the per-foot ranges before you decide. A glass guard outdoors still needs the same 1,070 mm height and the same 100 mm ball test as any other guard.

Ontario Building Code Stair Guard Height: How to Check Your Own Stairs

You can check your own stairs with a tape measure and a level. The Ontario building code stair guard height is 900 mm on a stair and 900 mm on a landing inside the home, so measure the guard at three points. Stair handrail height requirements in Ontario are checked the same way: measure the handrail from the nosing at the bottom, middle and top treads. If you are planning the whole staircase, our how to measure for a new staircase guide walks through the rise, run and opening first.

Check these six things, in this order:

  • Handrail height: measure from the nosing at three treads; it must sit between 865 mm and 1,070 mm at every one.
  • Guard height: measure from the nosing on the stair and the floor on the landing; at least 900 mm inside, 1,070 mm outside.
  • Baluster gaps: check every gap with a tape measure; no gap may be wider than 100 mm.
  • Posts: push each newel post firmly; a post that moves needs refixing first.
  • Glass condition: look for chips or cracks at the edges; a damaged panel must be replaced, not patched.
  • Landing guard: check the landing separately; a landing guard lower than the stair guard fails first.
What to check How to measure Code number
Handrail height From the tread nosing 865 mm to 1,070 mm
Guard on a stair From the tread nosing At least 900 mm
Guard on a landing From the floor At least 900 mm
Guard outside the home From the deck surface At least 1,070 mm
Baluster gaps Widest gap No more than 100 mm
Stair width Between finished walls At least 860 mm
Headroom From the nosings At least 1,950 mm
Riser and run Nosing to nosing 125 mm to 200 mm, 255 mm to 355 mm

What to Photograph

Photograph the handrail from the side at the bottom, middle and top of the flight, so the height at each tread is visible. Photograph the guard from the landing, and any gap that looks wide. Put the tape measure in one photo for scale, and photograph the newel posts at both ends.

Numbers to Double-Check

Re-measure the handrail height and the landing guard before you call anyone: these two numbers decide whether your stairs pass. If either one is low, write down the lowest reading and the tread it was taken at. A written record with photos is what an installer needs to quote the fix.

Minimum Handrail Height Ontario Stairs: What Happens If Yours Is Too Low

The minimum handrail height Ontario stairs must meet is 865 mm above the tread nosing, and a handrail below that line fails an inspection. Stair handrail height requirements in Ontario set 865 mm as the floor, not a suggestion: a handrail at 800 mm is too low to grip in a fall, and an inspector will not sign off a staircase that misses the minimum. A low handrail is also the defect a home inspector flags first at a sale.

The fix is usually simple: replace the handrail, raise it on new brackets, or fit a newel and rail at the right height. A handrail that is too low because the stairs were built to an older code still needs the current number when it is replaced. Ask for the fix in writing, with the height at three treads listed, so you can check it yourself.

7 Mistakes That Fail a Handrail Inspection

Most failed handrail inspections come from the same few slips, and every one is easy to avoid. Keep this list beside you when you check your stairs: in stair handrail height requirements in Ontario, a handrail that fails on one of these points is the most common reason a staircase is held up.

The seven mistakes, in the order they usually happen:

  • Measuring from the tread: height is measured from the nosing line, not from the tread surface.
  • Quoting 1,070 mm indoors: an interior landing takes a 900 mm guard, not the outside number.
  • Measuring on the level: the handrail follows the slope, so measure from the nosing at three treads.
  • Skipping the ball test: every gap must stop a 100 mm ball.
  • Fitting horizontal rails: horizontal members act as ladder rungs on a deck guard and can fail it.
  • Trusting an old handrail: a rail built to an older code still needs the current numbers.
  • Measuring once: check the bottom, middle and top treads, and keep the lowest reading.

How Darvish Inc Checks and Installs Code-Safe Handrails

Darvish Inc is a Toronto-area team installing stairs and railings across Toronto and the GTA, with glass and fittings made to your exact measurements. When you ask us about stair handrail height requirements in Ontario, the answer starts with a free on-site measurement: a handrail is measured tread by tread. Our own team measures every opening, prepares the drawings and installs the handrail. We have done this since 2017 with our own crew, never subcontractors. Our stair railing in Toronto page sets out the full process.

Every quote is written down line by line, so you can see the handrail, the guard, the drawings and the installation as separate items. Drawings are checked against the framed opening before anything is made. Once the heights are settled, the staircase installation cost in Toronto guide shows what those numbers mean for the finished staircase price.

Our work has earned four Consumer Choice Awards in York Region, from 2022 to 2025, and you can read Darvish Inc reviews from GTA homeowners on Google. We serve Toronto, North York, Vaughan, Markham, Richmond Hill and Oakville.

Final Thoughts on Stair Handrail Height Requirements in Ontario

Two numbers decide your stairs: the handrail at 865 mm to 1,070 mm, and the guard at 900 mm inside the home and 1,070 mm outside it. If you remember one thing, let it be this: stair handrail height requirements in Ontario come down to measuring from the nosing, checking the landing separately, and never quoting the outside number indoors. A handrail measured well is a staircase that passes the first time.

Measure twice, write every number down, and get an on-site measurement before you sign anything. Keep this guide with your check sheet, and your installer can quote from numbers instead of guesses. If you would like a number for your home, our team can measure your space and give you a written quote.

Frequently Asked Questions

What is the standard handrail height in Ontario?
▾

A handrail in Ontario must sit 865 mm to 1,070 mm above the tread nosing, measured from the nosing line. The Ontario building code stair guard height is a separate number: 900 mm on a stair and 900 mm on a landing inside the home, and 1,070 mm outside. Measure at three treads, and keep the lowest reading.

How high should a guard be on an interior landing in Ontario?
▾

A landing inside the home takes a 900 mm guard — not higher. The guardrail height for interior stairs Ontario is the same 900 mm as on the stair, and the handrail above it sits 865 mm to 1,070 mm above the nosing. The full set of stair handrail height requirements in Ontario treats the landing and the stair as one guard.

What is the minimum handrail height on stairs in Ontario?
▾

The minimum handrail height Ontario stairs must meet is 865 mm above the tread nosing. Below that line, a handrail fails an inspection and is too low to grip in a fall. The maximum is 1,070 mm, raised from 965 mm in 2022, and any new or replacement handrail must sit inside the current range.

Do deck railings in Ontario need to be higher than interior railings?
▾

Yes. A guard outside the home must stand 1,070 mm high, while an interior guard needs only 900 mm. The handrail stays the same in both places, at 865 mm to 1,070 mm above the nosing. A deck guard quoted at 900 mm uses the interior number, and it will fail an inspection.

Do I need a permit to replace a handrail in Ontario?
▾

A like-for-like handrail replacement usually needs no permit, but a permit is usually needed when you move a staircase, cut a new opening or change the structure. The stair railing code for decks in Ontario also applies to a deck guard replacement, so ask your municipality first.

FOLLOW US!

Follow us on social media to see all our latest projects and keep up to date with all the latest information regarding Darvish Inc and our services.

If you would like to stay informed about our latest news, please enter your email.

More Cases

Stair handrail height requirements in Ontario — Darvish Inc installer measuring a handrail in Toronto
Stair Handrail Height Requirements in Ontario: The 2026 Code Guide

A handrail too low will not save anyone from a fall, and one too high is hard to grip. In Ontario, the height is not a matter of taste: the

Stairs and railings in Concord shown on a staircase in a modern Concord home
Stairs and Railings in Concord: Custom Designs, Costs and Code Tips for 2026

Stairs and Railings in Concord: Custom Designs, Costs and Code Tips for 2026 A new staircase can change how a Concord home feels, but the first quote can surprise you

Person measuring a wooden staircase with a tape measure in a bright home
How to Measure for a New Staircase, Step by Step

A staircase that fits starts with numbers you can trust. Before anyone cuts a tread or orders a glass panel, the opening has to be measured properly, because a staircase