How to Measure for a New Staircase: A Step-by-Step Guide for 2026
A staircase that fits starts with numbers you can trust. Before anyone cuts a tread or orders a glass panel, the opening has to be measured properly, because a staircase is made to your exact measurements and a 10 mm error can mean a tread that does not sit level. This guide shows you how to measure for a new staircase the way our own team does it, from the total rise to the rough opening. You need only a tape measure, a level and a helper.
In this staircase measurement guide, we walk through the three numbers that decide everything: the total rise, the riser height and the tread run. You will also learn how to measure stair rise and run with a worked example, how to check the rough opening, and the steps for measuring stairs for a replacement railing. By the end, you will have a measurement sheet for any installer, and you will know whether your opening can take the staircase you want.
At Darvish Inc, our own team handles stairs and railings across Toronto and the GTA, from on-site measuring to the final install, so the advice below comes from real homes and real stairs. This guide covers how to measure for a new staircase in a home or a business, the code numbers behind every step, and the costliest mistakes. We serve Toronto, North York, Vaughan, Markham, Richmond Hill and Oakville.
What You Need Before You Measure
You need no special tools to measure a staircase, but you do need the right ones. A short tape will not reach a long run, and a measurement taken alone is rarely straight. Gather these six items first: the whole job takes about half an hour.
Check each item off before you measure:
- Tape measure: a 5 m tape suits most homes; 8 m helps on long runs.
- Level: a 600 mm or 1,200 mm spirit level for floors and treads.
- Straightedge: a long straight board to carry the upper floor line across.
- Pencil and paper: write every number down twice, and photograph each one.
- A helper: one person holds the tape at the top while the other reads below.
- Phone camera: photograph the opening, the stairs, and any beam or duct above.
How to Measure Stair Rise and Run

Every staircase is three numbers: the total rise, the riser height and the tread run. This is the heart of how to measure for a new staircase: the total rise decides the riser height, and the riser height decides the tread run. Work through the three steps in order, writing each number down before you move on.
Step 1: Measure the Total Rise
The total rise is the vertical distance from the finished floor below to the finished floor above — the most important number in the whole job. Measure finished floor to finished floor, never subfloor to subfloor: flooring adds thickness on both levels. Hold a straightedge level from the upper floor edge, measure down to the lower floor, then measure again at the other end. If the two numbers differ, keep the larger one: the staircase is cut to fit the opening as built.
Step 2: Divide the Rise Into Equal Risers
Divide the total rise by a target riser of about 175 mm and round to the nearest whole number: that is your riser count. Divide the total rise by the riser count for the exact riser height, and check it against the Ontario Building Code: every riser in a home staircase must sit between 125 mm and 200 mm. Keep risers uniform: within 5 mm of the riser beside them, within 10 mm across the flight. If the exact riser lands above 200 mm, add one more; if it lands below 125 mm, take one away and recalculate.
Step 3: Set the Tread Run and the Total Run
Pick a tread run between 250 mm and 280 mm. The Code allows a run from 255 mm to 355 mm, measured nosing to nosing, and the tread must be at least as deep as the run, no more than 25 mm deeper. Check the comfort rule: twice the riser plus one tread should land between 550 mm and 700 mm. The tread count is always one less than the riser count, because the upper floor acts as the last tread, so the total run is the tread count times the run.
| Measurement | How it is worked out | Example |
|---|---|---|
| Total rise | Finished floor to finished floor | 2,800 mm |
| Target riser | Comfortable step height | 175 mm |
| Number of risers | Total rise ÷ target riser, rounded | 16 |
| Exact riser height | Total rise ÷ number of risers | 175 mm |
| Number of treads | Risers − 1 | 15 |
| Tread run | Your chosen run, nosing to nosing | 250 mm |
| Total run | Treads × tread run | 3,750 mm |
| Comfort check | Two risers + one tread | 600 mm, inside 550–700 mm |
This worked example is the whole method for how to measure stair rise and run: one division, one rounding and one multiplication. Run the same check on your own numbers, and you have done the hard part of how to measure for a new staircase. If the comfort check lands outside 550 mm to 700 mm, change the tread run first: a small change there moves the total less.
How to Measure the Staircase Rough Opening Size
The opening is the hole in the upper floor that the staircase climbs through, and it decides whether the staircase fits. Getting the staircase rough opening size right matters more than any single tread: an opening that is too short fails the headroom rule, and one that is too narrow cannot be widened without cutting the floor. It is the step in how to measure for a new staircase that most people skip, so measure the opening in three places: length, width and headroom.

Opening Length and Headroom
Headroom is measured straight up from the tread nosings, and the Code requires at least 1,950 mm over the stair. The opening must be long enough for this clearance over every tread, so its length depends on your stair’s slope. With a 175 mm riser and a 250 mm run, the slope is 0.7, so 1,950 mm divided by 0.7 is about 2,800 mm — the length the opening needs from the upper floor edge. So the staircase rough opening size comes from the slope, not from the stair length. Check headroom again under any beam or duct, and note the lowest point.
Opening Width and Landings
Measure the opening width between the finished wall surfaces: plaster and trim take space the framing does not show. The Code requires a staircase inside a home to be at least 860 mm wide; most choose 900 mm or more so furniture can pass. A landing must be at least as wide as the staircase, and as long as the lesser of the stair width or 1,100 mm. A single flight may rise no more than 3.7 m, so a taller floor-to-floor height needs a landing and a second flight.
| Requirement | Code limit for a private staircase |
|---|---|
| Riser height | 125 mm to 200 mm |
| Tread run | 255 mm to 355 mm |
| Two risers + one tread | 550 mm to 700 mm |
| Stair width | At least 860 mm clear |
| Headroom | At least 1,950 mm above the nosings |
| Guard height | 900 mm on a stair, 1,070 mm on a landing |
| Handrail height | 865 mm to 1,070 mm above the nosing |
| Openings in a guard | No 100 mm ball may pass |
These are the 2024 Ontario Building Code limits for a private staircase inside a home, and the Ontario Building Code stair rules are the standard installers work to. Two numbers changed recently: the minimum run rose from 210 mm to 255 mm in 2022, and the handrail maximum from 965 mm to 1,070 mm in the same update. Treat the table as a planning reference, and confirm permit rules with your municipality first.
Measuring a Winder, L-Shaped or Curved Staircase
A winder turns a corner without a landing, using triangular treads narrow at one end and wide at the other. The Code allows winders inside a home to turn no more than 90 degrees, each tread spanning 30 to 45 degrees and neighbouring winders at the same angle. Measure each winder at the walk line, about 300 mm in from the narrow end, under the same rise and run limits as a straight flight.
A true spiral staircase follows its own numbers: at least 660 mm wide, risers no more than 240 mm, treads at least 190 mm deep 300 mm from the centre line, and headroom of at least 1,980 mm. If the turn is wider than 90 degrees, a landing is the safer choice, and our floating staircases in Toronto show how a landing can become a feature.
Measuring Stairs for a Replacement Railing
A replacement railing is measured differently from a new staircase: the stairs are already there, and the railing must follow their slope. It is a different job from how to measure for a new staircase, and the method for measuring stairs for a replacement railing starts at the newel posts, not at the floor. The slope — not the floor plan — decides the length of every panel and handrail, so measure twice: a glass panel cut to the wrong slope cannot be fixed.

Railing Length and the Slope
Measure along the slope from the bottom newel face to the top newel face, tape held tight to the rake. Record the horizontal run and the slope: a glass panel is cut to that slope, and a level measurement is not enough. Measure the height at both ends too: the handrail height at both newels should match, and if it does not, the stairs are out of level and the installer needs to know before cutting.
Baluster Spacing and Handrail Height
No opening in a guard may let a 100 mm ball pass through: that sets the baluster spacing on a wood or metal railing. The handrail must sit 865 mm to 1,070 mm above the tread nosing, and the guard at least 900 mm high on the stair and 1,070 mm on a landing. Glass panels are 10 mm or 12 mm tempered glass meeting the CAN/CGSB-12.1 standard. For the price side, the glass railing cost in Toronto guide breaks down the per-foot ranges before you decide.
Send these numbers with your photos, and check the posts too: a newel that moves when you push it needs refixing before the new railing goes on, because a railing is only as solid as the posts that hold it.
7 Mistakes That Ruin a Staircase Measurement
Most bad measurements come from the same few slips, and every one is easy to avoid. Keep this staircase measurement guide beside you and check each one off before you order: a staircase cut to the wrong numbers is the most expensive mistake. This is the part of how to measure for a new staircase where a second pair of eyes pays for itself.
The seven mistakes, in the order they usually happen:
- Measuring to the subfloor: always measure finished floor to finished floor — flooring adds thickness on each level.
- Forgetting the finished floor upstairs: measure to its finished surface, not to the bare joists.
- Not checking the floors are level: measure the total rise at both ends, keep the larger number.
- Measuring the run board to board: the run is nosing to nosing, and the tread depth includes a nosing up to 25 mm.
- Ignoring headroom: check 1,950 mm under the lowest beam or duct, not just under the open ceiling.
- Assuming the opening is square: measure both ends and the diagonals, then build to the smallest width.
- Measuring alone: one person holds the tape at the top while the other reads it, then swap and measure again.
What to Send Your Installer
A good installer needs eight numbers and a few photos, nothing more. This is the part of how to measure for a new staircase that turns your tape measure into a quote: fill in the sheet below with your own numbers and send it with the photos below.
| Measurement | What to record | Example |
|---|---|---|
| Total rise | Finished floor to finished floor | 2,800 mm |
| Number of risers | Total rise ÷ target riser, rounded | 16 |
| Riser height | Total rise ÷ number of risers | 175 mm |
| Tread run | Your chosen run, nosing to nosing | 250 mm |
| Total run | Treads × tread run | 3,750 mm |
| Rough opening length | Upper floor edge | 2,800 mm or more |
| Rough opening width | Between finished wall surfaces | 900 mm |
| Headroom | Lowest point above the nosings | 1,950 mm or more |
Photos to Include
Photograph the opening from above and below, the existing stairs from both ends, and any beam or duct above the stair. Put the tape measure in one photo for scale, and photograph the newel posts if you are replacing the railing.
Numbers to Double-Check
Re-measure the total rise and the opening length before you send anything: these two numbers decide everything else in how to measure for a new staircase. If either one changes, every riser, tread and panel changes with it. Once the sheet is ready, the staircase installation cost in Toronto guide shows what those numbers mean for the finished staircase price.
Send the sheet and the photos together, and ask for the quote in writing, every line item listed. This staircase measurement guide gives you the numbers; the installer gives you the price, and a written quote is the only fair way to compare installers.
How Darvish Inc Measures and Installs Your Staircase
Darvish Inc is a Toronto-area team installing stairs and railings across Toronto and the GTA, with the glass and fittings made to your exact measurements. When you ask us how to measure for a new staircase, the answer starts with a free on-site measurement: a staircase is measured tread by tread, and only a site visit prices it fairly. Our own team measures every opening, prepares the drawings, and installs the staircase cleanly. We have done this since 2017 with our own crew, never subcontractors. To see the service behind the numbers, our staircase in Toronto page sets out the full process.
Every quote is written down line by line, so you can see the staircase, the railing, the drawings and the installation as separate items. Drawings are checked against the framed opening before anything is made, and every project includes post-installation support.
Our work has earned four Consumer Choice Awards in York Region, from 2022 to 2025, and you can read Darvish Inc reviews from GTA homeowners on Google. We serve Toronto, North York, Vaughan, Markham, Richmond Hill and Oakville.
Final Thoughts on How to Measure for a New Staircase
Three numbers decide your staircase: the total rise, the riser height and the rough opening. If you remember one thing from this guide, let it be this: how to measure for a new staircase comes down to measuring the total rise first, dividing it into equal risers, and checking the opening for headroom before you order anything. A staircase measured well is a staircase that fits the first time.
Measure twice, write every number down, and get an on-site measurement before you sign anything. Keep this staircase measurement guide with your sheet, and your installer can quote from numbers instead of guesses. If you would like a number for your home or business, our team can measure your space and give you a written quote.
Frequently Asked Questions
How do I measure the total rise for a new staircase?
▾
Measure from the finished floor below to the finished floor above, with a straightedge held level from the upper floor edge and a tape down to the lower floor. Measure at both ends and keep the larger number. The total rise is the first number in how to measure for a new staircase, and it decides every riser that follows, so measure it twice.
How many risers do I need?
▾
Divide the total rise by a target riser of about 175 mm, round to the nearest whole number, then divide by that number for the exact riser height. Every riser must sit between 125 mm and 200 mm. That division is the core of how to measure stair rise and run, and the tread count is always one less than the riser count.
How big should the rough opening be?
▾
The opening must be at least 860 mm wide, and long enough for 1,950 mm of headroom over every tread. With a 175 mm riser and a 250 mm run, that works out to roughly 2,800 mm of length. The staircase rough opening size is set by headroom, not by the stair length alone, so measure under the lowest beam or duct.
Can I measure a staircase myself, or should I book a professional?
▾
You can measure for planning, and this guide shows you how to measure for a new staircase step by step. But the installer always re-measures before cutting: a 10 mm error can mean a tread that does not sit level. A free on-site measurement gives you a written quote based on your stairwell, the only fair way to compare installers.
How do I measure for a replacement railing?
▾
Measure along the slope from the bottom newel face to the top newel face, and record the horizontal run and the slope. Check the handrail height, 865 mm to 1,070 mm above the nosing, and the baluster spacing: no 100 mm ball may pass. That slope measurement is the key step in measuring stairs for a replacement railing: a glass panel is cut to the slope.